Cycle life test is one of the basic tests which Neware battery tester (BTS3000, BTS4000, BTS5000, BTS6000, BTS7000, BTS8000, BTS9000) can support.
Following example for your reference.
Battery model: Li-ion 18650, 2000mAh, 3.7V
Principle of battery cycle life test:
For example, the nominal charge and discharge cycle shall be "no less than 80% of the nominal capacity after 500 cycles”.
1. Full charge the battery to the nominal voltage--4.2V
2. Discharge the battery to the cut-off voltage--2.8V
3. Cycle step1 to step 2 500times.
4. Following step 1 and step 2 to charge and discharge again, record the discharge capacity. Compared this result with 80% of the original nominal capacity. Then you can judge whether this battery is up to standard or not.